8060 UPS changing state

Description

Refer to Diagnostic class (standard): 1

Filter type 13 extended system messages

With the assistance of the monitoring task, it is possible to respond to specific events in a fast task. The UPS uses this tool to delay the shutdown of the PacDrive controllers so that certain actions defined in an application can be executed before the system is switched off.

For this purpose, an event starting the configured monitoring task is triggered for the following changes in the UPS state machine:

UPS.State=3

UPS active – no power

UPS.State=4

UPS active – system shutdown started

UPS.State=6

UPS active – system temperature too high

The diagnostic message 8060 UPS changing state is indicated if a monitoring task already started by the UPS is still active at the following UPS state changes:

UPS.State=3

UPS.State=4

UPS.State=4

UPS.State=6

UPS.State=6

UPS.State=4