State

General

Type

AD

Devices supporting the parameter

Incremental Encoder Input

Traceable

Yes

Functional Description

Displays the availability and the validity of the encoder position data.

Value

Data type

Meaning

not ready / 0

DINT

The encoder or encoder processing is not ready.

Initialization / 1

DINT

Encoder processing is initialized.

not synchronous / 2

DINT

Encoder processing does not run synchronously with real-time processing (Sercos bus is not in phase 4). The velocity and position values of the encoder are not exact and therefore cannot be used.

ready / 3

DINT

The velocity and position values of the encoder are valid.