ET_DiagExt

 

ET_DiagExt - General Information

Overview

Type:

List type

Available as of:

V1.0.0.0

Description

The enumeration ET_DiagExt specifies the POU-specific diagnostic and status messages.

Enumeration Elements

Name

Value

Description

Ok

0

Proceeding normally, satisfactory or under control, or other affirmative acknowledgement.

Disabled

1

Disabled.

Initializing

2

Initializing.

WaitForStart

3

Wait for Start.

Working

4

In process.

WaitUntilStopped

5

Wait until drive has been stopped.

Disabling

6

Disabling.

DriveInvalid

8

Drive is invalid.

FoilWidthRange

10

FoilWidth is outside of the valid range.

CoilRadiusRange

11

CoilRadius is outside of the valid range.

FoilDensityRange

12

FoilDensity is outside of the valid range.

NumberOfAsyncTasksRange

13

NumberOfAsyncTasks is outside of the valid range.

UnexpectedFeedback

14

Feedback is not expected.

MaxNumberOfReusableObjectsExceeded

15

Maximum number of reusable objects has been exceeded.

MeasurementPeriodRange

16

MeausrementPeriod is outside of the valid range.

AccelerationRange

18

Acceleration is outside of the valid range.

DecelerationRange

19

Deceleration is outside of the valid range.

VelocityRange

20

Velocity is outside of the valid range.

JerkRange

21

Jerk is outside of the valid range.

SlaveMasterRatioRange

22

SlaveMasterRatio is outside of the valid range.

InterfaceInvalid

23

Interface is invalid.

UnexpectedState

25

State is unintended.

ParentInvalid

26

Parent is invalid.

ParentNotRegistered

27

Parent is not registered.

MaxNumberOfLoggerPointsExceeded

28

Maximum number of logger points is exceeded.

StartMovement

34

Start movement is executed.

ParameterInvalid

35

Parameter is invalid.

SensorValueMinMaxInvalid

36

SersorValueMin and SensorValueMax are invalid.

ApplicationValueMinMaxInvalid

37

ApplicationValueMin and ApplicationValueMax are invalid.

ApplicationLevelRefRange

38

ApplicationLevelRef is outside of the valid range.

AnalogInputInvalid

39

AnalogInput is invalid.

InvalidController

40

Controller is invalid.

DriveNotReady

41

Drive is not ready.

RadiusRange

44

Radius is outside of the valid range.

MasterInvalid

45

Master is invalid.

MaxStartDistanceRange

46

MaxStartDistance is outside of the valid range.

MaxStartDistanceReached

47

Maximum start distance is reached.

MiddlePosRangeRange

48

MiddlePosRange is outside of the valid range.

RadiusInvalid

50

Radius is invalid.

PreControllerModeInvalid

51

PreControllerMode is invalid.

ControllerModeInvalid

52

ControllerMode is invalid.

StartMovementModeInvalid

53

StartMovementMode is invalid.

UnexpectedDiagExt

54

DiagExt was not expected.

MasterStandStill

55

Master is at stand still.

MaxZoneRange

56

MaxZone is outside of the valid range.

MinZoneRange

57

MinZone is outside of the valid range.

FeedbackMaxReached

58

Maximum feedback is reached.

FeedbackMinReached

59

Minimum feedback is reached.

StartFillLevelRange

62

StartFillLevel is outside of the valid range.

DirectMasterInvalid

63

DirectMaster is invalid.

DisturbanceValueRange

64

DisturbanceValue is outside of the valid range.

JLoadGainRange

65

JLoadGain is outside of the valid range.

StartThresholdRange

67

StartThreshold is outside of the valid range.

CommunicationNotPossible

68

Communication is not possible.

ParameterNotConfigured

69

Parameter is not configured.

SignalOriginInvalid

70

SignalOrigin is invalid.

TimeOut

71

A TimeOut has occured.