Type |
AD |
Devices supporting the parameter |
PacDrive LMC x00C, OnBoard I/O, DIO8 module Bus terminals BT-4/DIO1 and BT-4/DIO1 TP |
Traceable |
Yes |
Displays the status of the measured input (Touchprobe TP).
The following can be displayed:
Values of the CaptureState parameter of the measured inputs for the FC_TPEdge()) function
Value |
Data type |
Meaning |
---|---|---|
inactive / 0 |
DINT |
The capture function is not enabled. |
active / 1 |
DINT |
FC_TPEdge() is enabled. |
captured / 2 |
DINT |
A valid measure value was recorded. |
overflow / 3 |
DINT |
Timeout of the pulse function (TP_Pulse()) |
disabled / 4 |
DINT |
The Touchprobe functionality is not available as Mode is not parameterized to "Touchprobe / 1". |
not ready / 5 |
DINT |
The Touchprobe function is not available as the Sercos bus is not in phase 4. |
virtual / 6 |
DINT |
The Touchprobe function is not available as the motor is virtual. |