Type |
EF |
Devices supporting the parameter |
Encoder network (Synchronization encoder output) |
Traceable |
Yes |
Enables the synchronization encoder output.
Value |
Data type |
Meaning |
---|---|---|
off / 0 |
BOOL |
The Synchronization encoder output is disabled. If the Synchronization encoder output is switched from "on / 1" to "off / 0" while the encoder network is enabled, the diagnostic message 8333 "EncNet receiving data not possible". Is sent to the Synchronization encoder inputs. |
on / 1 |
BOOL |
The Synchronization encoder output is enabled. Since all the controllers in the encoder network must be running synchronously and error-free for the encoder signals to be distributed, the parameter State displays the state of the Synchronization encoder output. If the value in the State parameter is "active / 5", an encoder signal is distributed. |