IF_RobotConfiguration - GetEmergencyParameter (Method)
Type: |
Method |
Available as of: |
V1.0.0.0 |
This chapter provides information on:
oTask
Reading the emergency parameters.
With the method GetEmergencyParameter(…), the configured data for an emergency stop of the robot can be read.
NOTE:
With the method GetEmergencyParameter, only data can be read:
oWritten with the method SetEmergencyParameter or
oWritten with the method SetEmergencyParameter2 and addressed with ET_RobotComponent.All.
Output |
Data type |
Description |
---|---|---|
q_etDiag |
General library-independent statement on the diagnostic. A value not equal to GD.ET_Diag.Ok corresponds to a diagnostic message. |
|
q_etDiagExt |
POU-specific output on the diagnostic. q_etDiag = ET_Diag.Ok -> Status message q_etDiag <> ET_Diag.Ok -> Diagnostic message |
|
q_sMsg |
STRING[80] |
Event-triggered message that gives additional information on the diagnostic state. |
q_lrDeceleration |
LREAL |
Parameterized deceleration (change of the velocity per time unit) with which the robot motion comes to a standstill in the case of a falling edge at FB_Robot.xEnable. Unit: [Units/s²] |
q_lrRamp |
LREAL |
Parameterized ramp (change of the deceleration per time unit) with which the robot motion comes to a standstill in the case of a falling edge at FB_Robot.xEnable. Detailed description of the motion parameter Ramp. Unit: [-] |
q_etDiag |
q_etDiagExt |
Enumeration value |
Description |
---|---|---|---|
OK |
0 |
Ok |
Enumeration name: |
Ok |
Enumeration value: |
0 |
Description: |
Ok |
Reading the configured emergency parameters of the robot was successful.