IF_RobotConfiguration - GetEmergencyParameter (Method)

Overview

Type:

Method

Available as of:

V1.0.0.0

This chapter provides information on:

oTask

oDescription

oInterface

oDiagnostic Messages

Task

Reading the emergency parameters.

Description

With the method GetEmergencyParameter(…), the configured data for an emergency stop of the robot can be read.

NOTE:

With the method GetEmergencyParameter, only data can be read:

oWritten with the method SetEmergencyParameter or

oWritten with the method SetEmergencyParameter2 and addressed with ET_RobotComponent.All.

Interface

Output

Data type

Description

q_etDiag

GD.ET_Diag

General library-independent statement on the diagnostic.

A value not equal to GD.ET_Diag.Ok corresponds to a diagnostic message.

q_etDiagExt

ET_DiagExt

POU-specific output on the diagnostic.

q_etDiag = ET_Diag.Ok -> Status message

q_etDiag <> ET_Diag.Ok -> Diagnostic message

q_sMsg

STRING[80]

Event-triggered message that gives additional information on the diagnostic state.

q_lrDeceleration

LREAL

Parameterized deceleration (change of the velocity per time unit) with which the robot motion comes to a standstill in the case of a falling edge at FB_Robot.xEnable.

Unit: [Units/s²]

q_lrRamp

LREAL

Parameterized ramp (change of the deceleration per time unit) with which the robot motion comes to a standstill in the case of a falling edge at FB_Robot.xEnable.

Detailed description of the motion parameter Ramp.

Unit: [-]

Diagnostic Messages

q_etDiag

q_etDiagExt

Enumeration value

Description

OK

Ok

0

Ok

Ok

Enumeration name:

Ok

Enumeration value:

0

Description:

Ok

Reading the configured emergency parameters of the robot was successful.