ET_DiagExt - General Information
Type: |
Enumeration type |
Available as of: |
V1.0.0.0 |
Versions: |
Current version |
The enumeration ET_DiagExt specifies the POU-specific diagnostic and status messages.
Name |
Value |
Description |
---|---|---|
0 |
The POU is disabled. |
|
1 |
Wait until all the trains are ready. |
|
2 |
Waiting for starting command. |
|
3 |
Wait until the cold start has been accepted. |
|
4 |
Wait until the cold start is completed. |
|
6 |
Wait until the warm start is completed. |
|
7 |
Wait until all the stations are ready. |
|
8 |
The MultiBelt is in automatic mode. |
|
9 |
All trains were stopped. |
|
10 |
Wait until all the trains are stopped. |
|
11 |
Wait for the reset of the start. |
|
12 |
Wait for CaptureOk of the trains. |
|
13 |
Wait until the trains are sorted. |
|
14 |
Internal state of the FB_MultiBelt. |
|
15 |
Wait until all the trains are deactivated. |
|
16 |
Wait until the homing is completed. |
|
20 |
Ok |
|
21 |
Diagnostic of the SystemLib |
|
22 |
Collision |
|
23 |
Diagnostic message of the Smg. |
|
24 |
The Sercos interface is invalid. |
|
25 |
Indeterminable state. |
|
26 |
The interface of the axis is invalid. |
|
27 |
A warm start is not possible. |
|
29 |
HomeTPOffset is outside the valid range. |
|
30 |
The distance between two trains is invalid. |
|
31 |
The sequence of the trains is invalid. |
|
32 |
The position of the train is outside the warm start window. |
|
33 |
The cycle time of the RTB is outside the valid range. |
|
34 |
The length of the belt is invalid. |
|
35 |
The interface Timer is invalid. |
|
36 |
The interface Limit is invalid. |
|
37 |
The distance between two TP signals was too large. |
|
38 |
The Tp cannot be found. |
|
39 |
A train is moving backwards. |
|
40 |
The EtDiagExt is invalid. |
|
41 |
The interface of the Tp is invalid. |
|
42 |
The interface SetLimit is invalid. |
|
43 |
NumOfStations is outside the valid range. |
|
44 |
NumOfBelts is outside the valid range. |
|
45 |
TrainsPerBeltRange is outside the valid range. |
|
46 |
CrashDistance is outside the valid range. |
|
47 |
BeltLength is outside the valid range. |
|
48 |
TrainLength is outside the valid range. |
|
49 |
The velocity for the warm start is outside the valid range. |
|
50 |
The jerk for the warm start is outside the valid range. |
|
51 |
The acceleration for the warm start is outside the valid range. |
|
52 |
The deceleration for the warm start is outside the valid range. |
|
53 |
The velocity of the start motion is outside the valid range. |
|
54 |
The acceleration of the start motion is outside the valid range. |
|
55 |
The deceleration of the departure move is outside the valid range. |
|
56 |
The jerk of the start moiton is outside the valid range. |
|
57 |
The velocity for a step is outside the valid range. |
|
58 |
The acceleration of a step is outside the valid range. |
|
59 |
The deceleration of a step is outside the valid range. |
|
60 |
The jerk of a step is outside the valid range. |
|
61 |
The help encoder was not set. |
|
62 |
DepartureDelay is outside the valid range. |
|
63 |
LockOutTime is outside the valid range. |
|
64 |
MinProductTime is outside the valid range. |
|
65 |
StartDelayTime is outside the valid range. |
|
66 |
ReadyForStepOffset is outside the valid range. |
|
67 |
TrainsDistanceFactor is outside the valid range. |
|
68 |
TrainsDistance is outside the valid range. |
|
69 |
StationPos is outside the valid range. |
|
70 |
NumOfSteps is outside the valid range. |
|
71 |
ProductsPerStep is outside the valid range. |
|
72 |
Steps is outside the valid range. |
|
73 |
The sum of the steps is invalid. |
|
74 |
AdditionalStep is outside the valid range. |
|
75 |
StopDistance is outside the valid range. |
|
76 |
Warning distance is outside the valid range. |
|
77 |
TrainTimeOut is outside the valid range. |
|
78 |
StartAcceptOffset is outside the valid range. |
|
79 |
StationLockOffset is outside the valid range. |
|
80 |
The interface RefActValues is invalid. |
|
81 |
The axis has not been set. |
|
82 |
HomeTp has not been set. |
|
84 |
The velocity for the homing is outside the valid range. |
|
85 |
The acceleration for the homing is outside the valid range. |
|
86 |
The deceleration for the homing is outside the valid range. |
|
87 |
The jerk for the homing is outside the valid range. |
|
88 |
TPSignalsPerTrain is outside the valid range. |
|
89 |
MaxTPSignalDistance is outside the valid range. |
|
90 |
MinTPSignalDistance is outside the valid range. |
|
91 |
The POU is being initialized. |
|
92 |
lrMasterPeriod is outside its value range |
|
93 |
The value of the parameter lrMinProductLength is outside its range. |
|
94 |
lrPhase is outside its value range |
|
95 |
lrSynchronEnd is outside its value range. |
|
96 |
lrSynchronStart is outside its value range. |
|
97 |
The sum of (SynchronStart + SynchronEnd) is outside its value range. |
|
98 |
The parameter lrStartDelayDistance is outside its value range. |
|
99 |
The GearFactor is outside its value range |
|
100 |
diUserCamId for the law of motion SystemCam is not assigned. |
|
101 |
The ControllerStopInterface is invalid. |
|
102 |
SkipSteps feature is not supported for synchron stations. |
|
103 |
This feature is not supported at present. For additional information refer to g_sMsg. |